Finden Sie schnell balkonkraftwerk komplettset testsieger für Ihr Unternehmen: 13 Ergebnisse

STS 5000 Multifunction substation test set

STS 5000 Multifunction substation test set

STS 5000 is a multifunction substation maintenance & commissioning test system for current, voltage and power transformers designed to perform primary tests requested in substations commissioning. It allows to perform accurate tests on CTs, VTs, PTs and ground grid. Main features Fully automatic Primary injection testing capabilities: up to 800 A or up to 5000 A / 7000 A, with the optional module BUX 5000 Variable output frequency: 15 – 500 Hz Power dissipation factor test with the optional module TD 5000 ( voltage up to 12 kV) 2000 v AC high-pot test Local control by large color display PADS – Power Apparatus Diagnostic Software for automatic testing, assessment and report IEC 61850-9-2 communication protocol Patented technology for Capacitance and Tan Delta measurement USB interface and Ethernet interface for PC connection. Compact and lightweight Tests performed CT ratio CT ratio voltage mode CT polarity CT burden secondary side ALF ISF CT excitation curve CT knee voltage CT winding resistance burden resistance voltage withstand rogowski coil low power transformer CT IEC 61850-9 VT ratio VT polarity VT burden secondary side VT IEC 61850-9 PT ratio PT vector group PT winding resistance OLTC tap changer dynamic resistance; PT excitation current PT no load current PT short circuit impedance PT leakage reactance Micro-ohmmeter CB operation time
Prüfstand mit kritischen Düsen für Balgengaszähler

Prüfstand mit kritischen Düsen für Balgengaszähler

Das Ing.-Büro IMBUS hat in Zusammenarbeit mit der holländischen Firma I METER eine neue Düsenprüfanlage für Balgengaszähler entwickelt. Diese Anlage wird zur Kalibrierung und Eichung von Zählern in einer Produktionsstätte genutzt und ist für die Zählergrößen G1.6, G2.5, G4 und G6 ausgelegt. Die Entwicklung der Anlage basierte auf folgenden Prämissen: vollautomatische und schnelle Prüfung, Optimierung und Reduzierung der benötigten Zeiten für die Dichtheitsprüfung unter Berücksichtigung der Anforderungen der PTB-Prüfregel Band 25 sowie ein einfacher Aufbau des Düsennormals ohne komplizierte Düsenwechseltechnik. Es wurde besonderer Wert darauf gelegt, dass jede Düse während der Nutzung permanent auf mögliche innere und äußere Leckagen geprüft wird. Für die Generierung der 3 Durchflüsse aller 4 Zählertypen sind insgesamt nur 9 Düsen erforderlich. Die Dichtheitsprüfung ist in 3 Prüfmodi unterteilt: Prüfung der Zählerbänke mit den Anschlüssen, Prüfung der Durchflussverrohrung vor den Zählerbänken und Prüfung der "double block and bleed" Ventiltechnik zusammen mit der "Düsen-Bypass" Kontrolle. Durch diese Aufteilung war es möglich, die benötigten Dichtheitsprüfzeiten je nach Zählertyp auf 2 bis 4,5 Minuten zu begrenzen. Zur Gewährleistung der Genauigkeit werden Referenzbehälter eingesetzt. Die Anlage wurde 2008 von der Firma Akhnaton LTD in Sofia gebaut, welche auch die Programmierung der Steuerung übernahm. Der Prüfstand wurde durch die holländische Eichbehörde NMI zugelassen und steht in Polen, wo die dort in Lizenz gebauten Balgengaszähler im Rahmen einer EU Zulassung gemäß der MID geprüft werden.
Prüftechnik für Schienen

Prüftechnik für Schienen

Wir übernehmen deutschland- und europaweit die Zerstörungsfreie Prüfung (ZfP), die Schienentechnik-Überwachung (SÜ) und die Qualitätsüberwachung Schienenbearbeitung (QüS) zur Inspektion und Dokumentation der Betriebssicherheit von Gleisen und Weichen. ZfP-Verfahren (821.2007) VT: Visual Testing (Sichtprüfung an Eisenbahnschienen) UT: Ultrasonic Testing (Ultraschallprüfung an Schienen- und Verbindungsschweißungen sowie Weichengroßteilen) ET: Eddy Current Testing (Wirbelstromprüfung nach der Schienenbearbeitung mit WPG) PT: Penetrant Testing (Farb-Eindring-Verfahren an Eisenbahnschienen) MT: Magnetic Testing (Magnetpulverprüfung an Eisenbahnschienen) Schienentechnik-Überwachung (824.5010; 824.8210; 824.8310) Überwachung und Durchführung der Herstellung lückenloser Gleise und Weichen Überwachung, Abnahme und Dokumentation sämtlicher Oberbauschweißarbeiten und Schienenbearbeitun
SOLARANLAGE DF60 HEIZUNG & WARMWASSER FASSADE/FLACHDACH

SOLARANLAGE DF60 HEIZUNG & WARMWASSER FASSADE/FLACHDACH

Solarthermische Anlage mit 60 df Röhren zur Brauchwassererwärmung und Heizungsunterstützung zur Installation an Fassade oder Flachdach. Art.-Nr. 18060 bestehend aus: 2 x Kollektor Weiser Power 3000 (Direct Flow Kollektor mit 30 Powerröhren) 1 x Set Gehäuseverbinder 1 x Set Enddeckel 2 x Befestigungsset Fassade oder Flachdach 1 x Anschlußset Wellrohr 3 x 20 kg Wärmeträgermedium VT51 df Allgemein: - 4-fach höherer Wirkungsgrad als bei Solarmodulen zur Stromerzeugung - 100% Made in Germany - dauerhafter Schutz des Vakuums durch patentierte Glas-Metall-Verbindung - witterungsbeständige Nanobeschichtung verhindert Schmutzanhaftungen - 20 Jahre Herstellergarantie - Röhren um 360° drehbar und optimal zur Sonne ausrichtbar - gleicher Röhrenabstand bei Verschaltung mehrerer Kollektoren - leichte Montage ohne schweres Werkzeug durch Steckverbindung - Röhren steckbar an Verteiler mit Schnellwechselmöglichkeit angeschlossen - für die optisch perfekte Anpassung an Dach und Fassade sind die Kollektoren in 213 RAL Farben lieferbar - Kollektoren sind TÜV geprüft nach DIN EN 12975-1:2006-06, DE EN 12975-2:2006-06, Solar Keymark Registernr.: 011-7S471R - Hagelschlag getestet nach: DIN EN 12975-2:2006
STS 5000 Multifunction substation test set

STS 5000 Multifunction substation test set

STS 5000 is a multifunction substation maintenance & commissioning test system for current, voltage and power transformers designed to perform primary tests requested in substations commissioning. It allows to perform accurate tests on CTs, VTs, PTs and ground grid. Main features Fully automatic Primary injection testing capabilities: up to 800 A or up to 5000 A / 7000 A, with the optional module BUX 5000 Variable output frequency: 15 – 500 Hz Power dissipation factor test with the optional module TD 5000 ( voltage up to 12 kV) 2000 v AC high-pot test Local control by large color display PADS – Power Apparatus Diagnostic Software for automatic testing, assessment and report IEC 61850-9-2 communication protocol Patented technology for Capacitance and Tan Delta measurement USB interface and Ethernet interface for PC connection. Compact and lightweight Tests performed CT ratio CT ratio voltage mode CT polarity CT burden secondary side ALF ISF CT excitation curve CT knee voltage CT winding resistance burden resistance voltage withstand rogowski coil low power transformer CT IEC 61850-9 VT ratio VT polarity VT burden secondary side VT IEC 61850-9 PT ratio PT vector group PT winding resistance OLTC tap changer dynamic resistance; PT excitation current PT no load current PT short circuit impedance PT leakage reactance Micro-ohmmeter CB operation time
STS 3000 LIGHT Multifunction substation test set

STS 3000 LIGHT Multifunction substation test set

STS 3000 light is a testing system designed to perform Tan Delta and capacitance measurement on CTs, VTs, Power Transformer and Circuit Breaker Main features Fully automatic Variable output frequency: 15 – 500 Hz Output voltage up to 12 kV Power dissipation factor test with the module TD 5000 ( voltage up to 12 kV) PADS – Power Apparatus Diagnostic Software for automatic testing, assessment and report USB interface and Ethernet interface for PC connection Compact and lightweight. Tests performed Tangent Delta Capacitance
STS 3000 LIGHT Multifunction substation test set

STS 3000 LIGHT Multifunction substation test set

STS 3000 light is a testing system designed to perform Tan Delta and capacitance measurement on CTs, VTs, Power Transformer and Circuit Breaker Main features Fully automatic Variable output frequency: 15 – 500 Hz Output voltage up to 12 kV Power dissipation factor test with the module TD 5000 ( voltage up to 12 kV) PADS – Power Apparatus Diagnostic Software for automatic testing, assessment and report USB interface and Ethernet interface for PC connection Compact and lightweight. Tests performed Tangent Delta Capacitance
18kV 10mA DC Tester PT18-10 MK2

18kV 10mA DC Tester PT18-10 MK2

Ultra lightweight (6.9kg) 1-200Adc test current with <2.5% ripple Supplied with standard 3m output lead set 0.1μΩ resolution mV, A, and m/μΩ displayed simultaneously USB memory key for data storage USB keyboard for comment entry Pre-settable test current with three buttons to store user test currents Large back-lit liquid crystal display Universal supply voltage 90-264V Optional current clamp to allows testing of objects with both sides earthed The PT18-10 mk2 high voltage dc test set is designed to perform tests on installed cable and jointing systems. The 18kV 10mA DC Tester has a variable output voltage with a maximum of ±18kVdc with a maximum charging capability of 10mA. A zero-volt interlock is fitted that prevents the output being switched on unless the output control is at zero. Units include an automatic load discharge system that discharges the cable under test when the output is switched off or a breakdown occurs. Internal dumping system can discharge a maximum of 2.5kJ on each output, corresponding to 10µF at 18kV. In the event of a test object failure, the overload circuit will automatically switch off the output voltage and earth the output via the internal discharge circuit. A DP20 discharge probe is supplied as standard with the PT18-10 mk2, 18kV 10mA DC Tester, allowing higher load capacitances to be safely discharged. The 18kV 10mA DC Tester has an internal fail-safe automatic discharge system with the following ratings: Max. discharge voltage (kVdc) 20kVdc Highest discharge energy 2.5kJ Highest discharge capacitance 10μF Max. discharges per hour 4 The automatic discharge switch is controlled by a solenoid. It may produce a noticeable hum when the HT output is energised. Output voltage is metered by two large, linear, analogue instruments marked 0-20kV. Meanwhile, current is metered by two further analogue instruments with 0-10 scale marking. The meters read 0-10mA directly, or 0-1mA when the ÷10 push button is operated. The HV output from the unit uses a high quality plug and socket system, allowing for easy cable replacement. High voltage plugs are protected in transit by plastic covers and are fully de-mountable. Screened 5 metre long high voltage output cables are provided with the equipment terminated with large clips. The mk2 units introduce automatic 115/230V mains voltage selection. That along the padded bag ensure maximum protection during transit.
MikroTest - Schichtdickenmessgerät

MikroTest - Schichtdickenmessgerät

Robustes Zinkdruckgussgehäuse Langzeitstabiler Magnet durch spezielles ElektroPhysik-Herstellungsverfahren Messbereich bis 20 mm Durch Gewichtskompensation in allen Lagen einsetzbar: Waagerecht, senkrecht, überkopf Messung auch auf gekrümmten Oberflächen Batterieloser Betrieb Datenblatt ..
30kV 10mA DC Tester PT30-10 MK3

30kV 10mA DC Tester PT30-10 MK3

±30kVdc output voltage. 10mA output capability. Both voltage and current metered on HV outputs. Automatic earth system for dumping capacitive loads. HV output plug & socket system. Key operated supply switch to prevent unauthorised operation. Zero-volt interlock. Visual indication of test piece failure. Automatic mains voltage selection. The PT30-10 Mk3 high voltage dc test set is designed to perform tests on installed cable and jointing systems. The 30kV 10mA DC tester has a variable output voltage with a maximum of ±30kVdc, with a maximum charging capability of 10mA. A zero-volt interlock is fitted that prevents the output being switched on unless the output control is at zero. The units include an automatic load discharge system that discharges the cable under test when the output is switched off or a breakdown occurs. The internal dumping system can discharge a maximum of 2.5kJ on each output, corresponding to 4µF at 30kV. In the event of a test object failure, the overload circuit will automatically switch off the output voltage and earth the output via the internal discharge circuit. A manual DP40 discharge probe is also supplied as standard with the PT30-10 MK3, 30kV 10mA DC Tester, allowing higher load capacitances to be safely discharged. The mk2 units introduce automatic 115/230V mains voltage selection, allowing easy transition between site voltages. The output voltage is metered by two large, linear, analogue instruments marked 0-30kV. Test object current is metered by two further analogue instruments with 0-10 scale marking. The meters read 0-10mA directly, or 0-1mA when the ÷10 push button is operated. The HV output from the unit uses a high quality plug and socket system, allowing for easy cable replacement.
SOLARANLAGE DF50 HEIZUNG & WARMWASSER FASSADE/FLACHDACH

SOLARANLAGE DF50 HEIZUNG & WARMWASSER FASSADE/FLACHDACH

Solarthermische Anlage zur Brauchwassererwärmung und Heizungsunterstützung zur Installation an der Fassade oder auf dem Flachdach. Art.-Nr. 18050 bestehend aus: 1 x Kollektor Weiser Power 3000 (Direct Flow Kollektor mit 30 Powerröhren) 1 x Kollektor Weiser Power 2000 (Direct Flow Kollektor mit 20 Powerröhren) 1 x Set Gehäuseverbinder 1 x Set Enddeckel 2 x Befestigungsset Fassade oder Flachdach 1 x Anschlußset Wellrohr 3 x 20 kg Wärmeträgermedium VT51 df Allgemein: - 4-fach höherer Wirkungsgrad als bei Solarmodulen zur Stromerzeugung - 100% Made in Germany - dauerhafter Schutz des Vakuums durch patentierte Glas-Metall-Verbindung - witterungsbeständige Nanobeschichtung verhindert Schmutzanhaftungen - 20 Jahre Herstellergarantie - Röhren um 360° drehbar und optimal zur Sonne ausrichtbar - gleicher Röhrenabstand bei Verschaltung mehrerer Kollektoren - leichte Montage ohne schweres Werkzeug durch Steckverbindung - Röhren steckbar an Verteiler mit Schnellwechselmöglichkeit angeschlossen - für die optisch perfekte Anpassung an Dach und Fassade sind die Kollektoren in 213 RAL Farben lieferbar - Kollektoren sind TÜV geprüft nach DIN EN 12975-1:2006-06, DE EN 12975-2:2006-06, Solar Keymark Registernr.: 011-7S471R - Hagelschlag getestet nach: DIN EN 12975-2:2006
SOLARANLAGE DF30 ANLAGE BRAUCHWASSER FLACHDACH/FASSADE

SOLARANLAGE DF30 ANLAGE BRAUCHWASSER FLACHDACH/FASSADE

Solarthermische Warmwasseranlage zur Brauchwassererwärmung zur Installation an der Fassade oder auf dem Flachdach Art.-Nr. 18030 1 x Kollektor Weiser Power 3000 (Direct Flow Kollektor mit 30 Powerröhren) 1 x Set Enddeckel 1 x Befestigungsset Fassade oder Flachdach 1 x Anschlußset Wellrohr 2 x 20 kg Wärmeträgermedium VT51 df Die Röhren können einzeln um 360° gedreht und somit immer optimal zur Sonne ausgerichtet werden, auch wenn der Installationsort nicht 100%tig nach Süden ausgerichtet ist.
SOLARTHERMISCHE ANLAGE HP90 ZUR BRAUCHWASSERERWÄRMUNG UND HEIZUNG

SOLARTHERMISCHE ANLAGE HP90 ZUR BRAUCHWASSERERWÄRMUNG UND HEIZUNG

Solarthermische Anlage mit 90 heat-pipe Röhren zur Brauchwassererwärmung und Heizungsunterstützung. Überhitzungssicher und nahezu wartungsfrei. Art.-Nr. 18190 Set für die Heizungsunterstützung und Brauchwassererwärmung bestehend aus: 3 x Kollektor Weiser Protect 3000-30hp 100°C (Weiser Protect Kollektor mit 30 Powerröhren und physikalischem Überhitzungsschutz bei 100°C) 2 x Gehäuseverbinderset 1 x Set Enddeckel 3 x Befestigungsset Aufdach 1 x Anschlußset Wellrohr 2 x 20 kg Wärmeträgermedium VT51 ALLGEMEIN • 4-fach höherer Wirkungsgrad als bei Solarmodulen zur Stromerzeugung • 100% Made in Germany • integrierter physikalischer Überhitzungsschutz bei 100°C • dauerhafter Schutz des Vakuums durch patentierte Glas-Metall-Verbindung • witterungsbeständige Nanobeschichtung verhindert Schmutzanhaftungen • 20 Jahre Herstellergarantie • Röhrenanschluss über Steckverbindung nach dem Heat Pipe Prinzip • trockene Anbindung der Röhren an den Sammler, somit können die Röhren ohne Ablassen der Anlage ausgetauscht werden • Röhren um 360° drehbar und optimal zur Sonne ausrichtbar • gleicher Röhrenabstand bei Verschaltung mehrerer Kollektoren • vielseitige Montagemöglichkeiten: Schrägdach, Aufständerung, Montagewinkel 10° – 80° • leichte Montage ohne schweres Werkzeug durch Steckverbindung • die Kollektoren sind in 213 RAL Farben lieferbar, somit ideal für die optisch perfekte Anpassung an Dach und Fassade • Kollektoren sind TÜV geprüft nach DIN EN 12975-1:2011-01, DIN EN 12975-2:2006-06, Solar Keymark Registernr.: 011-7S660R, Hagelschlag getestet nach: DIN EN 12975-2:2006